Waterless Urinals, waterless urinal, aquafree, aridian urinal falcon urinals, waterfree urinals
Gentworks Urinals
Gentworks Home Page About Waterless UrinalsAbout GentworksInformation IndexGentworks PoliciesContact Gentworks
Advanced search
 
Main Index Main Index
About Waterless Urinals
Converting to Waterless
Conversion Products
Costs and Savings
Aquafree
Armitage Shanks Aridian
Falcon Waterfree
Waterless Urinal Bowls
Low Flushing Method
Low Flushing Products
Flush Controllers
Installation and Servicing
Cleaning Products
Urinal Blocks

Further Info Further Info
Contact us
Privacy statement
Terms & Conditions
Information Index
Useful Documents
Buy Waterless Urinal Products
Waterless Urinals Pros and Cons
Waterless vs. Low Flushing
Guidance for Conversion to Waterless
Guidance for Conversion to Low-Flushing
Gentworks Engineers' Conversion Procedures
Maintaining and Cleaning Converted Urinals
Urinal Odours - Causes and Solutions
About Dead Legs
UMD Models
Aridian FAQs
Serviced Counties
Company Info
Policies
Consumer Customers

Waterless Urinals by Gentworks :: About Dead Legs

About Dead Legs
 
About 'Dead-Legs' and Legionella
 
 
If urinals are being converted to waterless operation, then you should assess the legionella risk from the standing water in the cistern and flushpipes. The simple solution is to drain the pipes and cistern at time of conversion and then cap the supply to the section of water pipes no longer required (known as 'dead-legs'). As an indication of cost, Gentworks engineers usually charge £60 per washroom for this work.
 
The Control of Substances Hazardous to Health 2002 say that you must carry out an assessment which will enable you to identify and assess potential sources of exposure. The vulnerability of the user group and the water systems present should be considered when carrying out your assessment. You must then introduce a course of action to prevent or control any risk you have identified and have a plan or procedure to deal with any incidents and emergencies.
 
Legionella are bacteria that are common in natural (rivers, lakes) and artificial water systems (storage tanks, pipework, showers). It can also be found in air conditioning systems and whirl pool spas. Legionnaires' disease is a potentially fatal form of pneumonia caused by the legionella bacteria. Breathing in water droplets contaminated by the legionella bacteria causes infection. It can affect anybody but mainly susceptible people such as the elderly, the young, the immunocompromised and those who are already ill. Legionella can survive in low temperatures, but thrive at temperatures between 20ºC and 45ºC. High temperatures of 60ºC and over will kill them.
 
 

The standard procedure to deal with dead-legs is:

1. Trace along the water supply pipes from the urinal cisterns to the nearest “tee” joint and then isolate the water supply by closing the nearest service valve or “stop-tap” below the “tee” joint. This may temporarily stop the water supply to other facilities.
 
2. With water supply isolated, sever the water supply pipe spur to the urinal cisterns as close as possible to the “tee” joint and install an additional isolation valve and end stopper.
 
3. The service valve below the “tee” joint can then be reopened to restore water supply to other facilities.
 
 
 
 
Your cart Your cart
Cart is empty
 

View cart
Checkout
Orders history

Authentication Authentication
Username

Password

Log in 
Register 
Recover password

If Javascript is disabled in your browser click here


Users online:  21 unregistered customer(s)
© Gentworks Waterless Urinals 2008    HTML Catalogue    Site Map